(Newcon Optik supplies all parts of the alignment).
Installation of the device is performed as follows:
Check the elevation of the fastening screws (2), pulling the rail
(3) to the body of the device (1) above the upper surface of the
rail. The elevation must not exceed the depth of the dead threaded
holes in the body of the device. In order to meet this requirement
you can cut the threaded part of the screws;
Prepare the glue according to its preparation instruction (the glue
need to be of certain strength not less than 200 kg/cm
2
, for
example epoxy), and put it on the surface (A) of the plate. The
surface of the screws must remain free of glue. This is especially
important for possibility to repair the device or to remove the
binding rail for installation on a different rifle;
Apply a hermetic substance (of silicone type) on the thread of the
screws (3);
Fix the rail to the body of the scope with the help of the screws
(3) cut at the required length;
Remove excessive glue (that is pushed out in the points where the
rail is connected to the body of the device) with the help of dry
cloth and alcohol-moistened cotton wool, and let the glue calcify
according to its instruction (for example, 24 hours for epoxy).
Place the scope on the rail of the rifle so that your eye coincides
with the edge of the Eyepiece Guard or in case of a large caliber
12
6. INSTALLING ON A HUNTING RIFLE
Night vision device DN482/483 may be used as a nighttime
hunting scope.
Recommendation. The usage of night vision riflescopes for
hunting may be limited or illegal in your area. Please, check with
local authorities prior to usage.
Device may be used with various mounts that facilitates reliable
fixation of the device to a particular rifle.
For convenient installation the device is supplied without stiff
fixation of the binding to the device, and in most cases that enables
to perform the device installation on a specific rifle model. For
installation you should contact a specialised armourer workshop
(gunsmith) or – if you are qualified enough – perform the
installation yourself.
INSTALLATION RULES.
a. Variant I – Adapter rail with Standard Prism type.
2 6 3 5 A 4 1
1- Device body
2- Front cradle for Standard prism
3- Rear feet for Standard prism
4- Mount of the Standard prism type
5- Fixing screws
6- Thwart screws
9
1- Body of the device
2- Adapter rail with 7/8’’ Weaver prism
encompassing
:
3- Fastening screws
4- Insert rest
5- Insert
6- Clamp (2 pcs.)
7- Clam
p
screw
(
2
p
cs.
)