Normal Shutdown Procedure
To shutdown the generator use the following procedure:
1. Place both the main circuit breaker (Figure 31) to the
OFF position.
2. Let the engine cool for 3-5 minutes with no load applied.
3. Turn the ignition key counter-clockwise to the STOP
position. When the engine has stopped, remove key.
Place key in a safe place where it will not be lost.
4. Inspect entire generator for any damage or loosening of
components that may have occured during operation.
TLG-12SPX4 — GENERATOR SHUT-DOWN PROCEDURES
NEVER stop the engine suddenly except in an emergency.
WARNING -
SHUTTING DOWN THE GENERATOR
Emergency Shutdown Procedure
1. Turn the ignition key counter-clockwise to the STOP
position. When the engine has stopped, remove key.
Place key in a safe place where it will not be lost.
2. Place both the main circuit breaker as shown in (Figure
31) to the OFF position.
3. After an automatic system shutdown, always find and
eliminate the problem before restarting generator.
Figure 31. Main Circuit Breaker (OFF)