Multiquip KD1800 Portable Generator User Manual


 
KD1800/KD6 A.C. GENERATOR — PARTS & OPERATION MANUAL — REV. #1 (06/16/05) — PAGE 29
KD1800/KD6 — MAINTENANCE (ENGINE)
When the anti-freeze is mixed with
water, the anti-freeze mixing ratio
must be less than 50%.
NOTE
Anti-freeze Recommendations
z
Use rubber gloves when handling anti-freeze.
z
When anti-freeze comes in contact with the skin or
clothing, wash it off immediately.
z
DO NOT mix different types of anti-freeze.
z
Keep fire, children and animals away from anti-freeze.
z
Check with local safety codes on the proper disposal
techniques of anti-freeze.
The battery is sufficiently charged if the specific gravity of
the battery fluid is 1.28 (at 68° F). If the specific gravity
should fall to 1.245 or lower, it indicates that the battery is
dead and needs to be recharged or replaced.
Check to see whether the battery cables are loose. Poor
contact may result in poor starting or malfunctions, always
keep the terminals firmly tightened. Coating the terminals
with a thin film of grease will help to inhibit corrosion.
The battery gradually deteriorates over time. The actual life
span will vary according to operating conditions, but generally
a battery two years or older should be replaced.
1. Make sure each
electrolyte
level (Figure 14) is to the
bottom of the
vent well
. If necessary add
distilled
water
in a well-ventilated area.
Battery
CAUTION:CAUTION:
CAUTION:CAUTION:
CAUTION:
z
NEVER let the battery's electrolyte
contact your body or clothing. ALWAYS
wear gloves when handling the battery.
z
ALWAYS wear eye protection and
rubber gloves when handling the
battery. Remember the diluted
sulfuric acid solution within the
battery burns skin and eats holes
in clothing.
z
If any part of your body comes in contact with the
sulfuric acid of the battery, immediately wash it off with
running water and get medical attention.
This unit is of negative ground. DO NOT connect in reverse.
Always maintain battery fluid level between the specified
marks. Battery life will be shortened, if the fluid level is not
properly maintained. Add only distilled water when
replenishment is necessary.
z
ALWAYS follow safety rules when
handling the battery. NEVER charge the
battery in a flammable environment.
ALWAYS keep open sparks and flames
away from the battery at all the times.
Figure 14. Battery Electrolyte
Level
Direction For Long Term Storage (Battery)
1. Remove the battery from the generator. Adjust the
electrolyte to the correct level, and store in a dry and
dark place.
2. Recharge battery once a month in summer, and every
two months in winter.