GB3LED LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (03/18/14) — PAGE 13
COMPONENTS
Figure 4 shows the location of the components for the
GloBug lighting system. The function of each component
is described below:
1. AC Power Cable — Connect this cable to a 120 VAC,
60 Hz power source.
2. Balloon — This balloon is made of heat-resistant
polyester, with a diameter of 33 inches (850 mm).
3. Balloon Cover/Carrying Case — When zipped, this
protective cover acts like a carrying case. The complete
lamp assembly is enclosed within the cover-carrying
case. Allow a sufficient amount of time for the lamp
to cool down before covering balloon. The possibility
exists of the balloon getting burned.
4. Mast — Two stage gas-assist mast. Maximum mast
height is 12.5 ft. (3.81 meters). When raising the mast,
always be on the lookout for overhead obstructions.
5. T-Handle Bolt Lock — Always tighten this lock to hold
the lamp/balloon securely in place before raising mast.
6. Weight Support Hook — To add additional weight to
the tripod and make the tripod more stable in windy
conditions. Place a sandbag or similar weight onto
this hook.
7. Tripod — Unbuckle velcro strap securing tripod legs
(3), push down on any tripod leg until all tripod legs
are fully deployed. To place tripod legs in the stowed
position, pull upward on velcro strap while pushing
down on tripod pole. Pull all legs upward and secure
with velcro strap.
8. Lamp Guard — This guard (cage) protects the lamp
from being hit by objects.
9. Lamp — Comprised of LED lamps. The lamps have
three stages of brightness: 300W, 200W, and 100W.
10. Tripod Carrying Case — Use this case when
transporting of the tripod is required. ALWAYS store
tripod in this carrying case when not in use.