Multiquip ga6HEB Portable Generator User Manual


 
ga6HB/6HeB
COMPONENTS (GENERATOR)
120/240V
30A
0N
OFF
IDLE
CONTROL
OPERATION
SWITCH
ON
OFF
120
V
GA-6HB
120
20A
120
30A
AC CIRCUIT BREAKER
GFCI PROTECTED
120
AC VOLTMETER
120V
FULL POWER
SWITCH
120V
120V/240V
MANUALRESET
P
O
W
E
R
F
A
U
L
T
120 V
20A
120 V
20A
10
4
12
8
11
1
IN SIMULTANEOUS USE 30AMP MAX
6 7
2
120/240V
30A
0N
OFF
IDLE
CONTROL
120
V
GA-6HEB
120
20A
120
30A
AC CIRCUIT BREAKER
GFCI PROTECTED
120
AC VOLTMETER
120V
FULL POWER
SWITCH
120V
120V/240V
MANUALRESET
P
O
W
E
R
F
A
U
L
T
120 V
20A
120 V
20A
IN SIMULTANEOUS USE 30AMP MAX
9
ELECTRIC START
14
START
SWITCH
OPERATION
SWITCH
13
9
3
5
Figure 3. Generator Components
1. NEMA L14-30R twist-
lock receptacle will provide 240V, 60 Hz @ 20.8 amps,
or 120V@ 41.6 amps (X2) 60 Hz. Depending on the
position of the full power switch.
2. NEMA L5-30R twist-lock
receptacle will provide 120V, 30 amps, 60 Hz.
3. NEMA L5-20R twist-lock
receptacle will provide 120V, 20 amps, 60 Hz.
4. Attach a rope or chain to this lifting
eye when lifting of the generator is required. Never
stand underneath the generator while it is being lifted.
Place lifting eye in down position when not in use.
5. Interrupts power when a
ground fault exist.
6. This 2-pole, 23 amp circuit breaker
protects the generator from short circuiting or
overloading. When starting the generator always have
the circuit breaker placed in the "" position.
7. This voltmeter indicates (with a
mark) the rated 60 Hz (single-phase) output voltage.
In addition the voltmeter can also be used as a
diagnostic tool. If the voltmeter indicator (needle) is
below the rated voltage, engine problems may exist
(low/high RPM's). To prevent damage to the generator
or power tools turn the generator  and consult your
authorized Multiquip service dealer.
8. The generator is provided with
an automatic idle control device for noise suppression
and reduced fuel consumption.
The automatic idle control automatically engages under
a no-load condition. With the automatic idle control
switched “ON”, the engine revolutions will automatically
drop to about 2600 rpm (low-speed operation) within
3 seconds after the load stops. When the operation is
resumed, the engine speed is automatically increased
to about 3600 rpm (high-speed operation) as soon as
the load is connected.
9.  Place switch in the "ON" position
(up) for normal operation. To turn-off the generator,
place the operation switch in the "OFF" position (down).
10. NEMA 5-20R, GFCI
receptacle will provide 120V@ 20 amps.
11. This ground connection point should be
connect to a good earth ground (ground rod).
12. A container filled with activated
charcoal that traps gasoline vapors emitted by the
fuel system.
13. Press this pushbutton switch to start
the generator (GA6HEB only).
14. This unit is equipped with a 12 VDC
battery. Replace with only recommended type battery
(GA6HEB only).