Multiquip GA-2.5H Portable Generator User Manual


 
GA-2.5H A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #5 (03/04/08) — PAGE 23
GA-2.5H — INITIAL START-UP (ENGINE)
This section is intended to assist the
operator with the
initial
start-up
of the trash generator. It is
extremely important that this section be read carefully before
attempting to use the generator in the field.
2. Place the
choke lever
(Figure 11) in the "
CLOSED
"
position if starting a
cold
engine.
Figure 10. Engine Fuel Valve Lever (ON Position)
Figure 11. Choke Lever
3. Place the
choke lever
(Figure 11) in the "
OPEN
" position
if starting a
warm engine
or the
temperature is warm.
4. Place the
engine ON/OFF switch
(Figure 12) in the "
ON
" position.
Starting the Engine
1. Place the engine
fuel valve lever
(Figure 10) to the "ON"
position.
Figure 9. Main Breaker (OFF Position)
CAUTIONCAUTION
CAUTIONCAUTION
CAUTION
DO NOT attempt to operate this
generator until the Safety, General
Information and Inspection sections
of this manual have been
read and
thoroughly understood
.
Figure 12. Engine ON/OFF Switch (ON)
5. Grasp the starter grip (Figure 13) and slowly pull it out. The
resistance becomes the hardest at a certain position,
corresponding to the compression point. Pull the starter
grip briskly and smoothly for starting.
Figure 13. Starter Grip
DO NOT pull the starter rope all the way to the end.
DO NOT release the starter knob after pulling. Allow it
to rewind as soon as possible.
CAUTIONCAUTION
CAUTIONCAUTION
CAUTION
Before Starting the Engine
1. Be sure to
disconnect all electrical loads
from the
generator
prior to starting the engine.
2. NEVER
start
the engine with the
main circuit breaker
in the “ON" position. Place the main circuit breaker
(Figure 9) in the OFF position.