Multiquip DCA-600SSK Portable Generator User Manual


 
PAGE 48 — DCA-600SSK — OPERATION AND PARTS MANUAL (STD) — REV. #7 (04/30/10)
Steps 20 thru 26 are referenced
for Engine Operating Panel
S/N 3698617~. See Figure 59
below. This unit does not have
an ignition switch or a throttle
handle. It does have an “
engine
speed switch
” that is used in
conjunction with the MPEC
unit.
NOTE
Figure 59. Engine Operating Panel
S/N 3698617~
DCA-600SSK — GENERATOR START-UP PROCEDURE (MANUAL)
20. Set the
battery ON/OFF switch
(Figure 60) to the “ON
position.
Figure 60. Battery ON/OFF Switch
Figure 60. Pre-Heat Button/ Lamp
21. Press and hold the engine preheat button (Figure 59)
until the preheat lamp is lit (ON).
22. Place the engine speed switch in the “
LOW
” position
(Figure 62).
Figure 63. Auto-Off/Reset-Manual Switch
23. Place the Auto-Off/Reset-Manual switch in the “
Manual”
position to start the engine (Figure 63). Once the engine
starts, let the engine run for 1-2 minutes. Listen for any
abnormal noises.
Figure 62. Engine Speed Switch (Low)
24. Once the engine is warm and the engine is running
properly, place the engine speed switch in the “
HIGH
position (Figure 64).
Figure 64. Engine Speed Switch (High)
25. Verify that the "Engine Running" status LED on the MPEC
unit (Figure 65) is "ON" (lit) after the engine has been started.
Figure 65. Engine Running LED (ON)
NEVER!
manually start the engine with the
main
,
GFCI
or
auxiliary
circuit breakers in
the ON (
closed
) position.
CAUTION:
BEFORE STARTING
Generator and Control Panel
26. Continue operating the generator as outlined in steps
11 thru 19 (pages 46-47).
Pre-Heat
Lamp
Pre-Heat
Button