Lubrication Oil
Fill the engine crankcase with lubricating oil through the filler
hole, but do not overfill. Make sure the generator is level.
With the dipstick inserted all the way, but without being screw
into the filler hole, verify that the oil level is maintained
between the two notches (Figure 28) on the dipstick. See
Table 9 for proper selection of engine oil.
Fuel
Fill the fuel tank with clean and fresh
diesel fuel. diesel fuel.
diesel fuel. diesel fuel.
diesel fuel.
DO
NOT fill the tank beyond capacity.
Pay attention to the fuel tank capacity when replenishing
fuel. Refer to the fuel tank capacity listed on page 26,
Specification Table 7.
The fuel tank cap must be closed tightly after fillin
g.
Handle fuel in a safety container. If the container does
not have a spout, use a funnel. Wipe up any spilled fuel
immediately.
CAUTION :
Never fill the fuel tank while the engine
is running or in the dark. Diesel spillage
on a hot engine can cause a fire or
explosion. If diesel spillage occurs,
wipe up the spilled diesel completely
to prevent fire hazards.
Coolant
Use only drinkable tap water. If hard water or water with
many impurities is used, the inside of the engine and
radiator may become coated with deposits and cooling
efficiency will be reduced.
An anticorrosion additive added to the water will help
prevent deposits and corrosion in the cooling system.
See the engine manual for further details.
DCA-500SSK — PRE-SETUP
Figure 28. Engine Oil Dipstick
When checking the engine oil, be sure to check if the oil
is clean and viscous. If the oil is not clean, drain the oil
by removing the oil drain plug, and refill with the specified
amount of oil as outlined in the Komatsu Engine
Owner's Manual.
liOrotoMdednemmoceR.11elbaT
erutarepmeT
egnaR
liOepyT
F°32~F°401
)C°5-~C°04(
03EAS
F°5~F°32
)C°51-~C°5-(
03-W01EASro02EAS
)°51-(C°5woleB03-W01EASroW01EAS