Multiquip dca25USI2 Portable Generator User Manual


 

OUTPUT TERMINAL PANEL FAMILIARIZATION

Loads can be connected to the generator by the output
terminal lugs or the convenience receptacles (Figure 11).
Make sure to read the operation manual before attempting
to connect a load to the generator.
To protect the output terminals from overload, a 3-pole, 60
amp main circuit breaker is provided. Make sure to switch
 circuit breakers to the OFF position prior to starting
the engine.
Figure 11. Connecting Loads
Over Current Relay
An over current relay (Figure 12) is connected to the main
circuit breaker. In the event of an overload, both the circuit
breaker and the over current relay may trip. If the circuit
breaker can not be reset, the reset button on the over
current relay must be pressed. The over current relay is
located in the control box.
Figure 12. Over Current Relay