PAGE 26 — DCA-25SSIU2 (50 HZ)— OPERATION AND PARTS MANUAL — REV. #0 (03/11/05)
Voltage Selector Switch
The
voltage selector
switch (Figure 16) is located above
the output terminal panel’s
Hard Wire Hook-up Panel
. It
has been provided for ease of voltage selection.
Voltage Selector Switch Locking Button
The voltage selector switch has a locking button to protect
the generator and load from being switched while the engine
is running. To lock the voltage selector switch,
press
and
hold
the
red button
located at the bottom of the switch.
Figure 16. Voltage Selector Switch
DCA-25SSIU2 (50 HZ)— GENERATOR OUTPUTS
Generator Amperage
Table 8 describes the generator’s current output capability
for both 1Ø-phase and 3Ø phase applications.
Generator Output Voltages
A wide range of voltages are available to supply voltage for
many different applications. Voltages are selected by using
the
voltage selector
switch (Figure 16). To obtain some of
the voltages as listed in Table 7 (see below) will require a
fine adjustment using the
voltage regulator
(VR)
control
knob
located on the control panel.
NEVER change the position of the
voltage
selector switch
while the engine is running. ALWAYS place circuit breaker
in the open position before selecting voltage.
CAUTION - CHANGING VOLTAGES
elbaliavAsegatloV.7elbaT
esahPeerhT
)elbahctiwS(
V002V022V042V614V044
esahPelgniS
)elbahctiwS(
V511V721V931V042V452
sgnitaRerepmArotareneG.8elbaT
2UISS52-ACDWKAVKV001V002V022V044
esahPelgniS4.41A/N2xA06A/NA06A/N
esahPeerhT0252A/NA5.96A06A03
8.0=rotcaFrewoP*