Mosquito Magnet Defender Insect Control Equipment User Manual


 
If your Mosquito Magnet fails to start, it may be the result of poor gas flow from the propane tank through the regulator to the trap.
The attached tool has been designed to reset the internal mechanisms of the propane regulator and release any back pressure
from your tank. Please follow these steps:
Shut down your Mosquito Magnet.
Completely close the propane tank valve by turning to the “Off” position. (turn valve clockwise)
Disconnect the regulator from the propane tank valve.
Screw the threaded end of the reset tool into the propane tank valve until it is fully engaged.
You may hear a small “hiss” sound. This is the pressure being released from the propane tank.
Note: the threads in the tank valve are left handed threads. (turn valve counter clockwise)
Screw the regulator connector to the opposite end of the reset tool until fully engaged.
Note: hold the reset tool to
prevent it from backing out of the tank.
The regulator and propane tank are now reset. Disconnect the reset tool from the
regulator connector and the propane tank.
Re-attach regulator connector to the propane tank valve.
Slowly turn the propane tank valve on .
Restart your trap.
SHUT DOWN INSTRUCTIONS
To shut down the Defender simply close the valve on the propane tank and switch to “Off” position.
DO NOT UNPLUG UNIT. MOSQUITO MAGNET DEFENDER MUST REMAIN PLUGGED IN FOR 5 MINUTES AFTER
SHUT DOWN OR UNTIL FAN STOPS TO AVOID HEAT DAMAGE.
Any open octenol or other added attractant packages should be removed and discarded. The net should also be
discarded prior to storing the Mosquito Magnet Defender.
STORAGE: Mosquito Magnet Defender should be stored indoors in the off-season. Cover unit with trap cover
(available at www.mosquitomagnet.com) or with a tarp and secure tightly at the bottom to keep out dust,
spider webs and other debris.
MAINTENANCE
FOR BEST RESULTS
Your trap will begin capturing immediately, but allow 4-6 weeks to interrupt the breeding cycles.
Should you experience an interruption of power, be sure to restart the trap.
Clear door must be closed tightly to maximize catch.
Never spray insecticide in or around trap.
DO NOT MOVE TRAP WITH TANK ATTACHED! TANK MUST BE DISCON-
NECTED FROM REGULATOR BEFORE TRAP IS RELOCATED TO AVOID
DAMAGE TO REGULATOR AND/OR TRAP.
BE ADVISED, DAMAGE
CAUSED FROM FAILURE TO COMPLY WITH THIS INSTRUCTION IS NOT
COVERED UNDER WARRANTY.
Trap can be left running in the rain.
If using lime or lawn regenerative compounds, be sure to shut down the
Mosquito Magnet first to prevent dust or fine mist from being drawn into trap
and clogging net.
A standard, outdoor rated extension cord may be used to increase your trap area.
Octenol cartridge does not disintegrate. Smell will dissipate over time.
1
2
3
4
5
6
7
8
9
Propane tank should be refilled every 21 days.
Empty or replace net every 21 days.
See added attractant packaging for maintenance/ replacement instructions.
Accessories can be ordered at www.mosquitomagnet.com
Store Octenol in a cool, dry place.
Clean net periodically for tree pollen or debris.
In the event the side screen becomes clogged, remove and clean gently with toothbrush and cold
water.
Periodically wipe down the outside of the Mosquito Magnet with a clean water damp cloth.
1
2
3
4
5
6
7
TANK CHANGING TIPS
When attaching the regulator handle to a tank after a tank change, be sure to fully tighten the regulator
handle onto the tank. No need to use tools, but do turn the handle as far as possible by hand. When this is
done, loosen the handle 1/4 turn, then re-tighten the handle. Frequently this action will result in additional
turns beyond the 1/4 turn. The purpose for this is to fully engage the regulator onto the tank. If the regula-
tor is not fully engaged, the flow of gas may be restricted to the point where the trap will show a gas empty
code. If this occurs, press the off button, close the tank valve, and remove the regulator from the tank. Re-
attach the regulator and try again.
8
11
12
GAS RESET TOOL INSTRUCTIONS
1
2
3
4
NOTE: It is recommended that you use the Quick-Clear valve before seasonal storage to avoid build-up of
contaminants during off-season.
Technical Support: 1-877-699-8727
Gas Reset Tool
Extinguish all smoking materials prior
to use of Gas Reset Tool.
5
6
7
8
9