DISMOUNTING LOADER
STEP 1 DRIVE THE TRACTOR ONTO FLAT CONCRETE and place the loader in the position shown in Fig 1.
STEP 2 Remove the stand legs from their stored position and place them in their dismount position. Slide the in-
ner tubes down to the extended position and secure them with the 3/4” pins. See Fig. 2.
FIG. 1
STEP 3 Gently lower the loader until the stand legs touch the ground. Please note that the stand legs are not de-
signed to withstand all of the down-force that can be generated with the lift cylinders, they are designed to support
the weight of the loader only. Rotate the bucket so that the cutting edge and stand legs are all resting on the
ground. See Fig. 3.
FIG. 4
STEP 4,5 Using a 1-1/2” socket or end wrench, remove the 1” retaining bolt that secures the V-block to the guide
block. See Figures 4,5.
STEP 6 Using the bucket cylinders, slowly flatten the bucket. This will start to lift the upright mast out of the pillar
mount, see Figure 6A. When the bucket is completely flat on the ground, the upright mast will be high enough to
back away from the loader. See Figure 6B
FIG. 5
FIG. 6A
STEP 7 Disconnect the hydraulic supply to the loader and slowly back away from the loader. See Figure 7.
FIG. 3
FIG. 2
Stand Legs
FIG. 7
FIG. 6B
Upright Mast