Meade LXD55 Telescope User Manual


 
53
Method 2: Axis Alignment Using Autostar
Perform this procedure during the daytime. You will need to have an unobstructed
view of an easily sighted landmark, such as a light post. Use a low-power eyepiece,
such as the supplied 26mm. This procedure assumes that you have some familiarity
with Autostar's menu structure (you will need to locate the "Setup: Telescope"
menu). If necessary, refer to
AUTOSTAR'S MENUS, page 25.
Note: For best result, perform this procedure after you have trained the
drive. See page 20.
1. Adjust the latitude T-handle screws (26, Fig. 1d) so that the latitude is set to
45° or higher. See Step #6, page 12, for information about setting the latitude
controls.
2. Refer to Fig. 42 while performing this step. The Dec. motor (B) must be posi-
tioned so that it is at the back of the mount. The optical tube (A) must be
approximately horizontal (i.e., parallel with the horizon) and the counterweight
shaft must be pointing straight down..
If using a Schmidt-Newtonian model, loosen the cradle ring locks knobs (C)
and move the optical tube until the eyepiece (D) points downward as shown in
the Fig. 42. Re-tighten the cradle ring locks.
If using a refractor model, use the diagonal assembly to rotate the eyepiece
to a convenient viewing angle during testing. However, be careful that the diag-
onal is placed flush against the focuser and tightened in place using the thumb-
screws. It is important that the diagonal does not slip during the procedure.
3. Make sure that both the R.A. and Dec. locks (17 and 33, Fig. 1d) are tightened
to a firm feel.
4. Turn on Autostar and go to "Setup: Telescope." Press ENTER.
5. Press one of the Scroll keys until "LXD 55 Adjust" displays and then press
ENTER. A message displays that tells you to center a landmark. If the landmark
is not visible in your eyepiece, lift and move the entire telescope and tripod
assemblytry not to move the tube too far from the horizontal position (no
more than 5° up or down), as described in Step #2. You may also use the fine
azimuth controls (27, Fig. 1d) for side to side movement and the Autostar
Up/Down Arrows for small adjustments to the declination axis.
6. Caution: Before pressing ENTER, step back from the telescope assembly,
as the telescope will begin to rotate about two axes. When the landmark is
centered (Step #5), press ENTER.
The telescope first moves 180° on the Dec. axis and then rotates 180° on the
R.A. axis. Autostar displays "Slewing....".
When the telescope has completed the 180° slew, the telescope will be under
the mount instead of over it. The counterweight shaft is now pointed upwards
and the cradle adjustment screws (Fig. 40) are easily accessible.
7. Autostar again prompts you to center the landmark you have chosen in the
eyepiece. Use the Arrow keys to center the object and then press ENTER.
8. The telescope moves again on the R.A. axis. Use the cradle screw adjustment
mechanism on the bottom of the cradle to center the landmark in the eyepiece.
To adjust the cradle screws, use the supplied hex key to loosen the two outside
screws. Then adjust the position of the landmark by tightening or loosening the
center screw. Perform this adjustment on both sets of screws. When finished,
retighten the outer screws. The axis is now aligned.
Note: This procedure maximizes the pointing accuracy of the telescope provid-
ed the telescope is always placed on the mount in the same fashion. A mark
made on the mount under the saddle will ensure this alignment is maintained.
Fig. 42: Method #2 Setup. (A) Optical
Tube; (B) Dec. Motor; (C) Cradle
Ring Lock Knobs; (D) Eyepiece.
Motor at
back of
mount