9
CHARGE
OFF
OIL
Battery
Discharge
Lamp
Oil Alert
Lamp
Figure 2 - Battery Discharge Lamp and Oil Alert Lamp Location
Continued
GENERATOR
FEATURES
Continued
FULL POWER SELECTOR SWITCH
The full power selector switch is on the control panel. The switch has two posi-
tions: 120 VOLT ONLY, and 120/240 VOLT.
120 VOLT ONLY: This position sends full power to the 120V receptacles only.
240V power is not available. Use this position when powering 120V items only.
120/240 VOLT: This position sends full power to the 120/240V receptacle. It also
powers the 120V receptacles at reduced wattage capacity.
IMPORTANT:
Do not move the full power selector switch while powering
electrical items. Unplug all items before moving switch. Failure to do so can
damage switch.
BATTERY DISCHARGE LAMP
The battery discharge lamp (see Figure 2, above) will light if battery charger is not
operating while engine is running. If this happens, the battery will not charge and
will eventually run down. Have battery charging circuit repaired by authorized
service person.
120V
ONLY
120
240V
FULL POWER
SELECTOR
120V
ONLY
120
240V
FULL POWER
SELECTOR
120 VOLT ONLY
Position
120/240 VOLT
Position
Figure 3 - Full Power Selector Switch