Repair
[3] DISASSEMBLY/ASSEMBLY
[3] -3. Motor Section (cont.)
DISASSEMBLING
(4) Disassemble Field as drawn in Fig. 5.
Fig. 5
Switch
Field lead wire
Handle cover
Ring terminal
Field
Field
1. Unscrew four 4x18 Tapping screws and remove Handle
cover.
3. Disconnect Ring terminals from Brush holders
with a Slotted screwdriver.
Note:
Tapping the edge of Motor housing
with a plastic hammer enables Field
to be removed easily.
4. Unscrew two 5x40 Tapping screws and remove
Field from Motor housing.
2. Disconnect Field lead wires from Switch.