STOPPING THE GENERATOR
(a) Turn off the power switch of the elec-
tric equipment and unplug the cord
from receptacle of the generator.
(b) Turn the no-fuse breaker to the "OFF"
position.
(c) Allow the engine about 3 minutes to
cool down at no-load before stopping.
(d)
Recoil starter model
Turn the engine switch to the position
"OFF".
Electric starter model
Turn the key switch to the STOP posi-
tion.
(e) Close the fuel cock.
OIL SENSOR
(a) The oil sensor detects the fall in oil
level in the crankcase and automatic-
cally stops the engine when the oil
level falls below a predetermined level.
(b) When engine has stopped automati-
cally, switch off generator's no-fuse
breaker, and check the oil level.
Refill engine oil to the upper level as
instructed on page 6 and restart the
engine.
(c) If the engine does not start by usual
starting procedures, check the oil level.
OPEN
CLOSE
CLOSE
OIL SENSOR
Do not remove OIL SENSOR PROBE when refilling with oil.
Remove oil filler cap on the opposite side of carburetor.
CAUTION
OFF
ON