Makita EG781AE Portable Generator User Manual


 
17
ENGLISH
Switch position Lower Voltage Receptacle Higher Voltage Receptacle
120V Activated full rated output N.A
120/240V Activated half of rated output Activated full rated output
FULL POWER SWITCH (Except EG301A)
Select the voltage using the FULL
POWER SWITCH in accordance with the
electrical appliance.
Refer to
TABLE 2.
120V
120V
240V
Change the FULL POWER SWITCH
after turning the AC circuit breaker
to "OFF".
CAUTION
TABLE 2
(1) CHECKING THE OPERATION
Overloaded ?
Please make it sure that the generator is not overload.
NOTE :
Most induction loads such as electric motors require three to five times more
wattage than their ratings during starting.
(2) STOPPING THE ENGINE
Turn off the switch of load.
Switch off generator's AC breaker.
Disconnect tool or appliance.
Turn the STOP SWITCH to the position "O" (OFF).
NOTE :
Allow the engine about 3 minutes to cool down at no-load before stopping.