Makita EG781AE Portable Generator User Manual


 
27
ENGLISH
CLEANING AND ADJUSTING
SPARK PLUG
(a)
If the plug is contaminated with carbon,
remove it using a plug cleaner or wire
brush.
(b) Adjust the electrode gap to 0.6 to 0.7
mm (0.024 to 0.028 in.).
Gap 0.6 to 0.7 mm
(
0.024 to 0.028 in.
)
CLEANING FUEL STRAINER
Dirt and water in the fuel are removed by
the fuel strainer.
(a) Remove the strainer cup and throw
away water and dirt.
(b) Clean the screen and strainer cup
with gasoline.
(c) Tightly fasten the cup to main body,
making sure to avoid fuel leak.
Spark plug : BR-6HS (NGK)