LG Electronics LSVFSD-LP Log Splitter User Manual


 
NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE.
4
Adhere to all local codes or in their absence the latest edition of The
National Fuel Gas Code ANSI Z223.1 or NFPA 54-latest edition which can
be obtained from The American National Standards Institute, Inc. (1430
Broadway, New York, NY, 10018) or National Fire Protection Association,
Inc. (Batterymarch Park, Quincy, MA, 02269).
State or local codes may only allow operation of this appliance in a vented
configuration. Check your state or local codes.
Seller of unvented propane or natural gas-fired supplemental room
heaters shall provide to each purchaser a copy of 527 CMR 30 upon
sale of the unit (Stand. This is a standard Unvented Propane or Natural
Gas-Fired Space Heaters
Shadowdance™ Gas Log appliances are certified by OMNI-Test Labora
-
tories to ANSI Z21.11.2 unvented room heaters standard. These gas log
appliances may be used as a space heat source for a room in conjunction
with an approved unvented firebox.
Additionally, these units are design certified by OMNI-Test Laboratories
to ANSI 21.60b / CSA 2.26b Decorative Appliance. For installation in
solid-fuel burning fireplaces.
As such, these units may be used as a vented gas log set in any wood-
burning fireplace that has been properly constructed to code, and in the
case of factory built fireplaces, installed in compliance with manufacturers
listing and installation instruction.
Use of the log sets covered by this manual in a properly vented wood-
burning fireplace which has had the damper blocked open as detailed
below, preclude consideration of the combustion and ventilation air and
clearance to combustible restrictions discussed herein.
When local codes require the damper to be fixed open, a damper stop must
be installed to prevent full closure of the fireplace damper and provide a
minimum 29 square inch flue opening at all times.
This appliance is for installation in a solid fuel burning fireplace
(masonry fireplace or manufactured fireplace) with a working flue and
constructed of noncombustible material.
The minimum permanent free opening of the fireplace chimney or
chimney damper must be at least 29 sq. inches based upon a minimum
chimney height of at least 15 feet. Chimney damper must be fixed in
a manner to maintain permanent free opening at all times.
NEW YORK CITY, NEW YORK (MEA)
Installation of these gas log heaters are approved in the state of New York
and are prohibited in New York City.
CODES
SEE TABLE 3 ON PAGE 16 FOR BTU INPUT AND GAS PRESSURE
REQUIREMENTS
Do not install these Dual-Listed Gas Log Appliances in a bedroom or
a bathroom as all units exceed maximum allowable BTU/hr input of
10,000.
Tools and Supplies Normally Required
External regulator (Propane models only)
Manual shut-off valve
Sediment trap
Piping complying with local codes
Pipe compound
Pipe wrench
Tee joint
Screwdriver
Burn-in Period
During the first few times of operation of this appliance there will be some
odor due to the curing of the paint and burning off of lubricants used
in the manufacturing process. We recommend that you open windows
and ventilate the house during the initial burns. The paint emits non-toxic
odors during this process.
Depending on your use, the burn-in period may take a few hours or a few
days. Also if you have a sensitive sense of smell you may notice slight
odors during operating after the burn-in period is over.
KEEP YOUR HOUSE WELL VENTILATED DURING THE BURN-IN PERIOD.
THE ODOR AND HAZE EMITTED DURING THE BURN-IN PERIOD CAN BE
QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR. MAKE
SURE SMOKE DETECTORS ARE NOT TOO CLOSE TO THE FIREBOX
(CHECK WITH YOUR LOCAL CODE FOR ALLOWABLE DISTANCES).