NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 7
Step 8. Slide the supplied 6” of 3/4” heat shrink tube over the (3) blower
harness wires. See Figure 8.
Figure 8
Step 9. Placing edge of wire loom at edge of blower cage, connect the
black blower lead wires to the wires on the blower harness, using
butt connectors already installed. NOTE: Trimming harness wires
to correct length may be necessary. See Figures 9 and 10.
Figure 9
Figure 10
Step 10. Reconnect the new ground wire to the motor stud. See Figure
11.
Figure 11
Step 11. Slide the heat shrink tube to the motor, covering wires and con-
nectors. See Figure 12.
Figure 12
Crimp on butt connectors to both wires
Heat shrink tube
Green Ground Wire
Wire Loom Tubing