Lennox Hearth 506033-35 Blower User Manual


 
2
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 2
Stove Back
Blower
INSTALLATION INSTRUCTIONS
Removing Existing Blower From Stove
Step 1.
UNPLUG POWER CORD AND ENSURE APPLIANCE IS COLD
Step 2. Using a 5/32 allen wrench/T-handle, remove the blower mounting
allen screws from blower, and remove blower from stove. See
Figure 2.
Figure 3
Step 3. Using a crescent wrench, remove the fan blade. NOTE: Fan nut is
reverse thread.
Step 4.
Using a 3/8” end wrench, remove the ground (green) wire from the
blower stud. See Figure 3.
Green Ground Wire
Step 5. Carefully remove the black heat shrink sleeve material from
blower wires.
Step 6.
Cut both butt connectors on the motor side. Note: Cut at the
connector being careful to not remove any more wire than is
necessary. See Figures 4 and 5.
Figure 4
Figure 5
Step 7. Strip blower wires and connect butt connectors to both. See
Figures 6 and 7.
Figure 6
Cut black wires on motor
side of butt connectors
Butt Connectors
Cut Wires Shown
Strip wires as shown