Blower Operation Guidelines
While in auto operation mode, the blower will turn off and on based on the
temperature of the stove. Auto operation ensures there is sufficient heat
build-up to warm the air being moved by the blower before the blower is
turned on. Likewise, when the stove cools off, the blower is turned off
Blower Operation
The blower can be operated manually or automatically (blower will
turn on when the stove is hot and turn off when the stove is cool).
The rocker switch on the control panel allows you to select between
manual operation or automatic operation as follows (see Figure 23):
MANUAL OPERATION: Turn rocker switch to the “MANU-
AL” position and adjust rheostat knob to the desired speed. The blower
will have to be manually turned “OFF” by rotating the rheostat knob
counterclockwise until it clicks.
AUTO OPERATION: Turn rocker switch to the “AUTO” posi-
tion and the rheostat to the ON position (rotate rheostat knob clockwise
until it clicks). When the stove warms up, the blower will automatically
turn on (adjust rheostat knob to the desired speed setting). When the
stove cools down, the blower will automatically turn off.
Rheostat Operation - The highest blower speed is obtained by turning
the rheostat knob clockwise until it clicks “ON”, then rotate towards
“HIGH” to increase blower speed. Rotate the knob clockwise for a
lower speed. To turn off, continue to rotate the knob counterclockwise
until it clicks “OFF.”
ROOM AIR
BLOWER
SPEED
CONTROL/OFF
TWO POSITION
SWITCH
MANUAL/TEMPERATURE
AUTO-RESET
TEMPERATURE
SWITCH N/O
POWER CORD
3-RED
3-RED
YLW
BLK
WHT
4-GRN
1-BRN
1-BRN
4-GRN
3-RED
NOTE: SWITCH CONDITIONS
GIVEN AT ROOMTEMPERATURE
N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN
= FEMALE DISCONNECT
= MALE DISCONNECT
= STUD CONNECTION
Figure 22 - Wiring Schematic
Figure 23 - Blower Controls
Blower Speed Control
Knob (rheostat)
Manual / Auto
Rocker Switch
to prevent circulating cool air. Depending on the size and intensity of the
fire it may be necessary to adjust the fan speed accordingly to ensure un-
interrupted fan operation. For example a small fire may require a slower
fan speed to keep the heat output by the fan consistent. If the blower is
operated in manual mode, it may be necessary to adjust the blower speed
as the fire begins to burn down and the stove is no longer hot enough to
effectively heat the air moved by the blower. If the air coming from the
blower feels cool, one should either decrease the blower speed or stoke
the fire to build up more heat.