Kohler Thermostatic Electric Shower Outdoor Shower User Manual


 
23
Appliance fails
to produce hot
water when set
on Medium/
High Heater
Setting.
ON II/III
Heater Tank failure.
Contact local water
company.
Replace.
Supply pressure below
0.2 bar.
Contact local water company.
Check mains water static
pressure.
AnyON
ON II/III
ON II/III Possible failure of the
Microswitch or thermal
switch.
Use a suitable continuity
device to check the continuity
of the Microswitch or Heater
Tank and replace parts as
necessary.
Water will not
turn off.
Power
Light
Heater
Setting
Low/Medium/
High
Probable Cause Possible RemedySymptom
No change in
temperature
between Low/
Medium/High
setting.
ON Any
ON Any
Insufcient mains water
pressure.
Contact local water company.
Possible failure of Flow
Valve, Microswitch, or
Heater Tank.
Use a suitable continuity
device to check the continuity
of the Microswitch or Heater
Tank and replace parts
as necessary.
ON Any
Inlet Valve, Solenoid, or
Start/Stop switch faulty.
Replace as necessary.
Maintenance
Handset - Cleaning
Clean with mild washing up detergent or
soap solution. Wipe dry with a soft cloth.
Poor shower performance can be
avoided by cleaning the spray plate.
Use thumb or soft cloth to wipe rubber
nozzles. The handset must be descaled
regularly.
Insufcient Water supply.