Kohler 20RESAL-SA4 Portable Generator User Manual


 
TP-6804 1/15 67Section 5 Scheduled Maintenance
Generator Set Model Spark Plug Gap
14RESA/RESAL
0.76 mm (0.030 in.)
Figure 5-4 Spark Plug Gap
1--514
Figure 5-5 Checking the Spark Plug Gap
1--511
Figure 5-6 Adjusting the Spark Plug Gap
5.4 Air Cleaner Service
Fire.
Can cause severe injury or death.
Do not smoke or permit flames or
sparks near fuels or the fuel system.
WARNING
Servicing the air cleaner. A sudden backfire can cause
severe injury ordeath. Do notoperate the generatorset with
the air cleaner removed.
5.4.1 Air Cleaner, 14RESA/RESAL
The engine has a replaceable high-density paper air
cleaner element. See Figure 5-7.
1
2
3
4
5
6
586536
1. Cover knob
2. Air cleaner cover
3. Element cover nut
4. Element cover
5. Air cleaner element
6. Air cleaner base
Figure 5-7 Air Cleaner Components
Check for a buildup of dirt and debris around the air
cleaner system. Keep this area clean. Also check for
loose or damaged components. Replace all bent or
damaged air cleaner components.
Note: Operating the engine with loose or damaged air
cleaner components could allow unfiltered air
into the engine causing premature wear and
failure.