Kohler 20RESAL-SA4 Portable Generator User Manual


 
TP-6804 1/1518 Section 1 Descriptions and Service Views
1.7 Accessories
The following optional accessories are offered for the
RESAand RESAL generator sets.
1.7.1 Carburetor Heater
An optional carburetor heater is recommended for
improved cold starting in locations where the ambient
temperature drops below 0_C(32_F). The carburetor
heater prevents condensation and carburetor icing.
The heater requires a continuous source of AC power.
See the generator set Installation manual for more
information.
1.7.2 Fuel Regulator Heater 20RESA
and RESAL only)
An optional fuel regulator heater for the
20RESA/20RESAL is recommended for improved cold
starting in locations where the ambient temperature
drops below --18_C(0_F). The heater requires a
continuous source of AC power.
See the generator set Installation manual for more
information.
1.7.3 OnCue Plus Generator
Management System
The Kohlerr OnCuer Plus Generator Management
System allows monitoring and control of your generator
set from your home or other location with Internet
access using a computer or mobile device.
OnCuer Plus can be configured to send email or text
message notifications in the event of a generator set
fault.
OnCue Plus Wireless is also available. OnCue Plus
Wireless works with the customer’s wireles Ehternet
router and does not require the installation of a network
cable between the generator set and the c ustomer’s
router/modem.
1.7.4 Programmable Interface Module
(PIM)
The optional Programmable Interface Module (PIM)
provides two programmable inputs and six
programmable dry contact outputs for connection to
customer-supplied equipment. The outputs are
controlled by the RDC2or DC2 controller, and can also
be controlled remotely using OnCue Plus.
The PIM is mounted in a NEMA 3R aluminum
enclosure, which can be mounted indoors or outdoors.
See the installation instructions provided with the PIM.
1.7.5 Load Control Module (LCM)
The optional Load Control Module ( LCM) provides an
automatic load management system to comply with
Section 702.5 of NEC 2008. The installer is responsible
for ensuring that the power system installation complies
with all applicable state and local codes.
Note: The LCM is only compatible with single-phse
generator sets. Do not attempt to use the LCM
with 3-phase models.
The LCM automatically manages up to six r esidential
loads. Four power relays are provided for management
of non-essential secondary loads, and two relays are
available to control two independent air conditioner
loads.
The LCM is controlled by the RDC2or DC2 controller.
The load on the generator set is monitored, and loads
are added or shed in the order of their priority. See
specification sheet G6-120 and the LCM installation
instructions for more information.
1.7.6 Concrete Mounting Pads
Kohler offers optional concrete mounting pads that are
custom-designed for Model 14RESA/RESAL and
20RESA/RESAL generator sets. Three-inch and
four-inch thick pads are available. Four-inch pads are
recommended for storm-prone areas.
1.7.7 Emergency Stop Kit
An emergency stop button is available as a loose kit.
Pressing the emergency stop button causes the
generator set to shut down immediately. The generator
controller displays an emergency stop shutdown
message after the button is pressed.
1.7.8 Battery Heater Kit
The battery heater kit includes a thermostatically-
controlled battery heating wrap to warm the battery in
cold weather. Battery heater kits are recommended for
generator installed in regions where the temperature
regularly falls below 0_C(32_F).