TP-6335 9/04 Reconnection/Adjustments 33
Parameter Setting Definition
Unit’s system voltage
and frequency
Uu01 Single phase, 60 Hz, 120/240 VAC
Unit configuration Uc02 Mobile generator set
Engine type Ec03 10/13/15ERG
Engine data input types
(
N
i
i
k
)
Ed00 All digital inputs
g
p
y
p
(No magnetic pick-up)
Ed01 Digital: Low coolant level and low oil pressure
Analog: Low coolant temperature
Ed02 Digital: Low coolant level and low coolant temperature
Analog: Low oil pressure
Ed03 Digital: Low coolant level
Analog: Low coolant temperature and low oil pressure
Ed08 Digital: Low coolant temperature and low oil pressure
Analog: Low coolant level
Ed09 Digital: Low oil pressure
Analog: Low coolant level and low coolant temperature
Ed10 Digital: Low coolant temperature
Analog: Low coolant level and low oil pressure
Ed11 All analog inputs
Battery voltage Bt12 Battery voltage 12 VDC
Communications Cn00 No CAN communications
Cn01 SAE J1939 (Used for ADC remote digital gauge)
Cn02 Future CANbus
Figure 8-8 Controller Parameters