English HDS Super, HDS 695 S, HDS 745, HDS 895 S, HDS 995, HDS 1195, HDS 1295 6
NOTE ON THE OPERATING INSTRUCTIONS
All of the item numbers described below in the
operating instructions are referenced in the
illustration of the unit.
COMMISSIONING
– Unit, piping, high-pressure hose and
connections must be in perfect working order!
– Lock the hand brake.
Checking oil level
Figure 1
Contact Kärcher AFTER-SALES SERVICE
immediately if oil is opaque!
If oil level is approaching MIN mark, fill up with
oil as far as MAX mark.
Seal oil filler inlet.
Refer to technical data for oil grade.
Filling with scale inhibitor
Figure 2
(sample pack included with scope of delivery)
Scale inhibitor stops heating coil becoming
calcified when using hard tap water. Is is
metered in at the inlet in the water reservoir one
drop at a time.
The metering is set at the factory to medium-
hard water.
For other water hardness classes, call in
Kärcher AFTER-SALES SERVICE to perform
adjustment to local conditions.
Filling with fuel
– Never operate unit with fuel tank empty! Fuel
pump would otherwise be destroyed!
Figure 3
Only fill with diesel fuel or light fuel oil.
It is forbidden to use unsuitable fuels,
e.g. benzine (explosion hazard, damage to
unit).
Close tank cap
Wipe off excess fuel
Filling with cleaning agent
* Only use Kärcher products.
* Never pour in solvent (petrol, acetone, thinner
etc.)!
* Avoid contact with eyes and skin
* Pay attention to cleaning-agent
manufacturer's instructions on safety and
handling
Kärcher can provide an individual range of
cleaning and treatment agents.
Your dealer will be pleased to advise you.
Figure 4
Fill with cleaning agent
Mounting handgun
– Connect steel pipe (item 15) with handgun
(item 20)
– Insert high-pressure nozzle in union nut
– Mount and tighten unit nut
– Mount the high-pressure hose to the high-
pressure connection.(Figure 6)
Mounting of spare high-pressure hose
Figure 5
Mounting handle
Figure 7
Water connection
For connected loads, refer to Technical Data.
Install the supply hose to the water inlet
(item 18) of the unit.