John Deere PR-G7500M Portable Generator User Manual


 
OPERATING THE GENERATOR
Operator’s Manual 17
CONTROLS
CONTROL PANEL:
The generators are equipped with the following items:
PR-G3200M:
• Circuit Breaker
• One 125 Volt, 20 Amp, Duplex (2 outlets), GFCI protected
receptacles.
PR-G5500M:
• Circuit Breakers
• Two 125 Volt, 20 Amp, Duplex (2 outlets), GFCI protected
receptacles.
• One 125/250 Volt, 20 Amp, Locking Type Receptacle.
PR-G7500M:
• Circuit Breakers
• Two 125 Volt, 20 Amp, Duplex (2 outlets), GFCI protected
receptacles.
• One 125/250 Volt, 30 Amp, Locking Type Receptacle.
NOTE: The 125 Volt, 30 Amp locking receptacles ARE NOT GROUND
FAULT PROTECTED. If ground fault protection on these receptacles
is necessary or desired, external protection devices must be used.
Refer to the section on “Ground Fault Interrupter” for more informa-
tion.
WARNING: NEVER EXCEED THE RATING OF A
RECEPTACLE. THESE RECEPTACLES ARE
PROTECTED AGAINST OVERLOADS BY RESETTING
MAGNETIC TYPE CIRCUIT BREAKERS. IF A
CIRCUIT BREAKER TRIPS, THE CAUSE SHOULD
BE DETERMINED AND CORRECTED PRIOR TO
CONTINUING USE.
CONTROLS
OIL WARNING DEVICE:
NOTE: This engine is equipped with a “Low Oil” shutdown system for
engine protection. The engine stops when the oil level gets too low.
The engine will not restart without adding oil. If the unit is tilted too
much during operation, it may suddenly stop even though the oil
level is not low.
Check the engine oil before restarting the engine. If the unit is
tilted, level the engine, then check the oil before restarting the
engine.