John Deere HR-G1700i Portable Generator User Manual


 
Operating the Generator
Operator’s Manual 29
OPERATION
CABLE SIZE:
When a long electric extension cord is used to connect an appliance or
tool to the generator, a certain amount of voltage drop or loss occurs in
the extension cord which reduces the effective voltage available for the
appliance or tool. The chart below has been prepared to illustrate the
approximate voltage loss when an extension cord of 300 feet (approx.
100 meters) is used to connect an appliance or tool to the generator.
Equipment damage can result from low voltage. Therefore, to prevent
excessive voltage drop between the generator and the equipment,
the cable should be of adequate gauge for the length used. The cable
selection chart gives the maximum cable lengths for various gauges of
wire which can adequately carry the loads shown.
CURRENT LOAD IN WATTS MAXIMUM CABLE LENGTH (FEET)
IN AMPS 120 VOLTS 240 VOLTS #8 WIRE #10 WIRE #12 WIRE #14 WIRE #16 WIRE
2.5 300 600 1000 600 375 250
5 600 1200 500 300 200 125
7.5 900 1800 350 200 125 100
10 1200 2400 250 150 100 50
15 1800 3600 150 100 65
20 2400 4800 175 125 75 50
25 3000 6000 150 100 60
30 3600 7200 125 65
40 4800 9600 90