Whirlpool Bath: Installation and Operation Page 11 BE76000F • December 2007
ENGLISH
ELECTRICAL CONNECTION
3-Prong
plug from
control box
Route electrical connection from pump to control
box and from control box to duplex receptacle
FLOOR
*4 inch minimum (or in accordance with local
building or electrical codes
4” *
Duplex receptacle
(Not provided)
ELECTRICAL CONNECTIONS
A separate circuit, which must be protected by a Ground Fault
Circuit Interrupter (GFCI), is required. Install a duplex outlet
codes. The duplex outlet is not provided.
DANGER: Risk of electric shock. Connect only to a circuit
protected by a Ground Fault Circuit Interrupter.
RELOCATING THE BLOWER MOTOR
The 800W units come with a fused control box. For
convenience and/or accessibility, the blower motor (and fused
control box on 800W units) can be installed in a remote location.
IMPORTANT: Normally the Ozone equipment is connected to
the Blower equipment. Because the Ozone equipment should be
kept with the air bath, you need to provide a dedicated GFCI at
15 A for the Ozone equipment.
NOTE: The blower motor (and fused control box on 800W units)
must be relocated as a unit.
A separate circuit, which must be protected by a Ground Fault
Circuit Interrupter (GFCI), is required in the remote location.
Electrical connections should be performed by a licensed
electrician. The remote location must be service accessible.
The total length of the air pipe must not require more than 15’
(4.57 m) of piping and 6 directional changes. Pipe diameter
)
blower must not be installed in an attic area.
NOTE: Do not remove the inverted U and check valve, see
attached to the piping via a screw. Glue the air pipe and let set
overnight before attaching the blower with screw.
NOTE: Installing the Blower in a remote location will reduce
CAUTION: It is imperative to let the glued blower air pipe set
overnight as there may be fumes from the glue that could be
ignited if not allowed to dissipate.
Provide adequate ventilation in the remote location for cooling
of the blower must not be blocked, restricted or have any debris
around it that can potentially be sucked into blower. Insulation on
the air pipe length can reduce heat loss.
NOTE: Relocated blower requires a service access for the
control box and blower.
REMOTE LOCATION IN ADJACENT SPACE
Check
Adjacent space
Screw
Connect only
to a GFCI
protected circuit
Control cable
to blower
Do not remove
inverted “U”
FLOW
REMOTE LOCATION UNDER FLOOR
Check
valves
Screw
Connect only to a GFCI
protected circuit
Control cable
to blower
Do not remove
inverted “U”
FLOW
Control line
FLOOR