14.6 Panel Flashes FL1 or FL2
A ashing “FL1” display means the ow switch is
malfunctioning open, the lter cartridge is excessively
dirty or an “air lock” condition has occurred at the
circulation pump intake. A ashing “FL2” display means
the ow switch is malfunctioning closed. In either case,
the spa heater will deactivate and jets pump #1 may
also deactivate. To correct condition perform the following:
Verify water level is above all jets but below lowest pillow. Add water 1.
if necessary.
Check for clogged or dirty lter cartridge (sec. 12.1, page 2. 30).
Purge “air lock” from circulation pump intake by removing lter 3.
cartridge. Hold your garden hose over the lter cartridge wall tting
while using a rag as a seal around hose end. Ask a helper to turn
on water for 30 seconds, then turn off. Reinstall lter cartridge and
check spa (sec. 12.1, page 30).
If the circulation pump is not running, turn power off at the main 4.
breaker, then turn power back on. This will reset the circulation pump
priming cycle. Once the pump is primed, the error should clear.
If problem persists, contact your au5. thorized Jacuzzi dealer.
14.7 Panel Displays OH
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)

!
Water temperature is above acceptable limits. DO NOT ENTER SPA!
Water temperature has reached 112˚F (44˚C) and the low
speed jets pump 1 and optional circulation pump (when
equipped) has activated to circulate water through heater.
Contact your authorized Jacuzzi dealer or qualied service
technician.
To correct condition:
Remove the spa's cover and allow your spa to cool down.
Program the lter settings for Economy Mode (page 28). Raise water
temperature setting to cancel Summer Logic condition (page 38).
If the condition persists, contact your authorized Jacuzzi dealer.
14.8 Panel Displays (- - -)
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)

!
Water temperature is above acceptable limits. DO NOT
ENTER SPA! The safety “Watchdog” software has been
triggered and the spa is deactivated. A problem has been
detected which could cause damage to the spa or its components.
Contact your authorized Jacuzzi dealer or qualified service technician.
39