J-300 Series

F0 5 minutes of ltration per day (one 5 minute “Blow-Out”
cycle every 24 hours to purge all plumbing lines)
F1 1 hour of ltration per day (one 30-minute cycle every 12
hours); This is the factory default setting.
F2 1.5 hours of ltration per day (one 30-minute cycle every
8 hours)
F3 2 hours of ltration per day (one 30-minute cycle every 6
hours)

F4 1 hour of ltration/heating per day (one 30-minute cycle
every twelve hours)
F5 1.5 hours of ltration/heating per day (one 30-minute
cycle every eight hours)
F6 2 hours of ltration/heating per day (one 30-minute cycle
every six hours)
Lock Modes
L1 Lock Out: disables all spa functions to permit lter
cleaning.
L2 Lock Mode: disables the jets and light buttons to prevent
unauthorized use of spa. Filtration/heating cycle will
continue to operate as programmed in this mode. The temperature
display ashes when this function is enabled. Example: The “F3”
ltration/heating cycle was enabled prior to choosing lock mode. The
spa continues to perform the “F3” cycle until lock mode is canceled,
allowing another cycle to be selected.
To set a time for the rst ltration/heating cycle, simply turn power on to
the spa two minutes prior to the desired time. Example: If you desire
your rst ltration/heating cycle to begin at 10:00 AM turn off power to the
spa and turn it back on again at 9:58 AM.
Note: Start time is approximate and may vary slightly from day to day.