Jacuzzi J - 230 Swimming Pool Vacuum User Manual


 
J-200
8. Loosen the hose clamp on the circulation pump (if equipped) intake
behind the control box (Figure A, page 17) and pull the hose off (twist
hose back and forth while pulling outward). Tip hose down and allow
to drain, then reinstall hose and clamp.
9. Re-install synthetic cabinet side panel and cover spa so that no
casual moisture can enter into it.
Consult your authorized Jacuzzi dealer if you have any questions
regarding winter use or winterizing.
12.8 Restarting Your Spa in Cold Weather
If you want to start up your spa after it has sat empty for a time in freezing
temperatures, be aware that the water remaining in certain sections of the
piping may still be frozen. This situation will block water ow preventing
the spa from operating properly and possibly damaging the equipment.
We recommend you consult your authorized Jacuzzi dealer for guidance
before attempting to re-start your spa under these conditions.
13.0 Water Quality Maintenance
To decrease the risk of contracting a waterborne illness (e.g. an infection,
bacteria or virus) and/or respiratory ailments
, m
aintain water quality
within specied limits. This will enhance your enjoyment and prolong
the life of the hot tub’s equipment. Doing so requires regular attention
because the water chemistry involved is a balance of several factors.
Procrastination in regard to water maintenance will result in poor and
potentially unhealthful conditions for soaking and even damage to your
hot tub investment. For specic guidance on maintaining water quality,
consult your Authorized Jacuzzi dealer who can recommend appropriate
chemical products for sanitizing and maintaining your hot tub.
WARNING: FAILURE TO MAINTAIN WATER QUALITY
CAN RESULT IN:
Increase risk of contracting a waterborne illness (e.g. an
infection bacteria or virus) and/or respiratory ailments
.
Damage the equipment, components and spa shell, which
are not covered under the hot tub’s warranty.
!
CAUTION: Never store hot tub chemicals inside the hot tub’s equip-
ment bay. The equipment bay may reach elevated temperatures,
this is where high voltage electronic devices are located. This area
is not intended for storage of any kind.
13.1 pH Control
pH is a measure of relative acidity or alkalinity of water and is measured
on a scale of 0 to 14. The midpoint of 7 is said to be neutral, above which
is alkaline and below which is acidic. In spa water, it is very important
to maintain a slightly alkaline condition of 7.4 to 7.6. Problems become
38