J-300
230V/20A* 230V/30A** 230V/40A***
Circuit Breaker: 20A 30A 40A
Number of Wires: 3 3 3
Frequency: 50 Hz 50 Hz 50 Hz
Current Draw: 15A 23A 29A
*
In 20A conguration, the heater will not operate while either jets
pump is running in high speed. This is the factory setting. Note:
pump 2 runs only in high speed.
**
In 30A conguration, the heater will operate while one jets pump
is running in high speed. Note: pump 2 runs only in high speed.
***
In 40A conguration the heater will operate while both jets pumps
are running in high speed.
Export J-315 and J-325 Models (50Hz)
230V/20A* 230V/30A**
Circuit Breaker: 20A 30A
Number of Wires: 3 3
Frequency: 50 Hz 50 Hz
Current Draw: 15A 21A
In 20A conguration, the heater while the jets pump is running in
high speed. This is the factory setting.
In 30A conguration, the heater while one jets pump is running in
high speed.