29
8.1C No Heat Or Not Enough Heat
• Symptoms: Circulation pump (heating pump) not turning, panel heat indicator not lit,
panel is  ashing FL1.
Standard Troubleshooting Approach
Is there correct voltage
coming to the hot tub at
TB1?
240 VAC, +/-10%, or
(120/240 VAC, +/-10%
for J315/J325 models).
Replace circuit
board.
Repair connection.
Call an electrician.
Put hot tub in standard
filtration mode (page
21). Set temperature
high enough to initiate a
heat call. Is voltage ok
from circuit board to
circulation pump?
Test points 16 and 17 for
circulation pump.
No
No
Ye
s
Ye
s
Replace pump.
Yes
No
Is connection OK from
circuit board to pump?
Circuit Board Illustrations
A. 2002+ Protech LED Models (Page 50-51)
Note: Refer to the voltage and current charts on appendix page 46-47 for expected voltage/current readings.
Danger: Electrical Shock Hazard Exists!
High Voltage Present On Circuit Board. Use Ex-
treme Caution While Servicing Circuit Board.