Jacuzzi J-230 Hot Tub User Manual


 
page 21
10.0 Operating Instructions
The spa control system has automatic functions that operate upon start-
up and normal operation to protect the system. Upon power up, the
readout displays the following information:
1. Control panel displays current software release (e.g.
5.54), then;
2. Control panel displays “888” and all indicator LEDs
are lit, permitting visual inspection of all display seg-
ments and indicator lights for proper operation.
3. After the initial start-up sequence ends, the actual
water temperature is displayed. If water temperature
at this time is less then the factory default temperature
setting of 100°F (38°C) and the spa is set to either standard skim
-
ming/heating mode “F1-F3” (page 22), the heater will turn on and
run until the water temperature rises to the factory setting, then turn
off. Note: it is common for the heater to turn on after the spa is first
filled because tap water is often very cold.
10.1 Setting Water Temperature
The spa’s thermostat provides optimum control of water tem-
perature. The temperature set point (set temperature) can be
adjusted from 65°F to 104°F (18°C to 40°C). To raise the set
temperature, press the WARMER ( + ) button. To lower the
set temperature, press the COOLER ( - ) button. Note: The first press
of either WARMER ( + ) or COOLER ( - ) button displays the set tem-
perature.
10.2 Activate Pumps
The JETS 1 button activates the functions of the main
2-speed jets pump 1. The first press activates pump 1 in
low speed, the second press activates high speed, and the
third press shuts the pump off. The JETS 2 button (J-230
only) controls jets pump 2 as follows:
US/Canada 60Hz Models: Pump 2 runs in high speed only.
Export 50Hz Models:
The first press activates jets pump 2 in low
speed, the second press activates high speed, and the third press
turns jets pump 2 off.
Both jets pumps have a twenty-minute default when manually activated.
10.3 Light Button
The LIGHT button activates the spa light when pressed.
The light has a one-hour default.
1.
2.
3.