Invacare 3750 Hot Tub User Manual


 
SECTION 4—MAINTENANCE
Part No 1150695 33 Recessed Side Entry Bath Tubs
13. Turnthedisinfectantvalvetotheonposition.
NOTE:Liquidwillbeheardfillingtheinteriorplumbingofthetub.
14. Notethepositionofthefloatingballintheflowmeter.
15. Adjusttheinjectorbyperformingoneofthefollowing:
BottomofFloatingBallReadsGreaterThan35‐Lessdisinfectantneedstobe
addedtothemixture.Loosenthescrewontheinjectortodrawlessdisinfectant
intothesolution.
BottomofFloatingBallReadsLessThan35‐Moredisinfectantneedstobeadded
tothemixture.Tightenthescrewontheinjectortodrawmoredisinfectantintothe
solution.
16. Whenthebottomofthefloatingballisnear35,turntheblackadjustmentknobonthe
flowmeteruntilthebottomofthefloatingballisat35.
17. Placethebucket/pailundertheburpfittingtocollectthedisinfectant.Useafunnelif
necessary.
18. Notethenumberofouncesinthegraduatedplasticbottle.
19. Letthebucket/pailfilltoonegallon.
20. Turnthedisinfectantvalvetotheoffposition.
21. Removethedisinfectantdrawtubefromtheplasticbottle.
22. Examinetheamountofdisinfectantremainingintheplasticbottle.
23. SubtracttheamountofdisinfectantremainingfromtheamountnotedinSTEP18.
24. Performoneofthefollowing:
Approximately½ounceofdisinfectanthasbeenused‐ProceedtoSTEP23.
•Muchmoreormuchlessthan½ounceofdisinfectanthasbeenused‐repeat
STEPS118.
25. Positionthedisinfectantdrawtubeintothedisinfectantsolution.
26. Disinfectthetub.RefertoDisinfectingtheTubUsingtheClosedLoopSystem
on
page 23.
FIGURE 4.1 Calibrating the Disinfectant Flow Meter
Service
Access
Cabinet
Floating
Ball
Knob
Flow Meter
Disinfectant
Valve
DETAIL “A” -
FLOW METER
Screw
Injector
Disinfectant Siphon Tube