Infinity CD-7 THRU CD-15 Portable Generator User Manual


 
5
2. Remove and clean air filter.
- Remove filter housing to access filter.
- Rinse filter in warm, soapy water and blow dry.
- Replace filter.
3. Perform general cleaning of cabinet interior.
ANNUALLY:
1. Remove, disassemble and clean CD module.
See GENERATOR SERVICING section 4C.
BIANNUALLY:
1. Rebuild compressor.
See GENERATOR SERVICING section 4C.
4C. Generator Servicing
Before performing any servicing to the ozone generator,
make sure the power is off by disconnecting electrical
plug from wall socket.
4C-1. Corona Discharge (CD) Module
1. Disconnect the wires from the thermostat switch and
ground terminal attached to the generator housing.
2. Unplug high voltage cable(s) from the top end of
the CD module.
3. Very carefully disconnect the oxygen feed and
ozone output lines by removing the stainless steel
compression nuts.
4. Drain cooling water from ozone module and dis-
connect cooling water lines.
5. Remove module from cabinet.
6. Carefully remove glass end housing, inspect for
damaged glass or retainer springs, and set aside.
7. Remove the opposite end (aluminum discharge end)
taking care not to lose retainer springs. Inspect for
damage and set aside.
8. Gently glide glass tube electrodes out from module.
Inspect for damage.
9. Wipe down electrodes using a solvent such as de-
natured alcohol and set in a safe area.
10. Swab out the stainless steel tubes using a solvent
such as denatured alcohol or acetone.
11. Replace electrodes -
be sure to wipe off any finger-
prints
, and reassemble module in reverse order.
4C-2. Air Compressor
Air compressor requires a rebuild every two (2) years
or 15,000 hours of operation.
1. Purchase rebuild kit from DEL Industries, Inc.
See Section 5 for ordering information.
2. Follow instructions in kit to rebuild compressor.
4D. Trouble Shooting
Knowledge of electrical applications is required for
trouble shooting. Contact a certified electrician if you
are unsure of your ability to service the equipment.
If any condition persists, call 800-676-1335 for
technical assistance.
Symptom:
Main power
light out when system switch is
in the "ON" position.
1. No power to the generator module from the power supply:
a. Check the circuit breaker at the facility power dis-
tribution box.
b. Check for loose connections or wiring breaks
from the power distribution box to the generator.
Figure 4: Component Locations
CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator