Husqvarna HUV4210-G Utility Vehicle User Manual


 
Batteries – Electric Vehicles
Page 38 2008 Husqvarna 4210-G, 4210-E, 4210-GXP, and 4210-EXP Owner’s Manual
1. The batteries should be kept clean and free of corrosion. Wash tops and terminals of batteries with a
solution of baking soda and water (1 cup (237 mL) baking soda per gallon (3.8 L) of water). Rinse solution
off of the batteries. Do not allow this solution to enter the battery. Be sure terminals are tight. Let the ter-
minals dry and then coat with Battery Terminal Protector Spray (Husqvarna 603 00 00-03). See follow-
ing NOTE.
NOTE: Dispose of waste water properly.
2. The electrolyte level in the batteries should be checked weekly (Figure 21). Add water only after charg-
ing unless the electrolyte level is below the top of the plates. In this case, add just enough water to cover
the plates, charge and then check the level again. Never charge batteries if plates are exposed above
electrolyte level. For best battery life, add only distilled water. See following CAUTION and NOTE.
ý CAUTION
Do not overfill the batteries.
NOTE: A battery watering gun or bottle is available at many auto parts dealers.
3. The hold-down straps should be tight enough so that the batteries do not move while the vehicle is in
motion, but not so tight as to crack or buckle the battery case. Tighten hold-down retaining nuts to 40 in-
lb (4.5 N·m). The terminal connections should be clean and tight, and any worn insulation or frayed wires
should be replaced. Tighten battery terminals to 110 in-lb (12.4 N·m). See following CAUTION.
ý WARNING
If battery wire terminals are damaged or corroded, replace or clean them as necessary. Failure
to do so may cause them to overheat during operation and could result in fire, property
damage, or personal injury.
4. After use, the batteries should be placed on charge. The batteries should never be left discharged any
longer than absolutely necessary (do not leave discharged overnight).
Figure 21 Battery Electrolyte Level
1. Level Indicator 2. Cap 3. Plates
Electrolyte level at least 1/2 inch (13 MM) above plates or to level
indicator.
1
3
2