Husqvarna 536 LIL Trimmer User Manual


 
22 – English
MAINTENANCE
Troubleshooting schedule
Troubleshooting takes place from the keypad.
Keypad
Troubleshooting the battery and/or the battery charger during charging.
Battery
Battery charger
Control panel Possible faults Possible action
Green activate LED flashing. Low battery voltage. Charging the battery
Error LED flashes.
The power trigger and the activate
b
utton are pressed at the same
time.
Release the power trigger and the
machine is activ
e.
Overload.
The trimmerhead is jammed.
Remove the battery from the
machine
. Release the trimmer
head from grass.
Temperature deviation. Allow the machine to cool down.
The machine will not run Dirt in battery connectors.
Clean with compressed air or a soft
brush.
Error LED is lit with red light. Service Contact your service agent.
LED display Possible faults Possible action
Green activate LED flashing. Low battery voltage. Charge the battery
Error LED flashing.
The battery is discharged. Charge the battery
Temperature deviation.
Use the battery in surroundings
where temper
atures are between -
10
°C and 40 °C.
Over voltage.
Check that the mains voltage
corresponds with that stated on the
r
ating plate on the machine.
Remove the battery from the
batter
y charger.
Error LED is lit. Cell difference too much (1V). Contact your service agent.
LED display Possible faults Possible action
Error LED flashing. Temperature deviation.
Use the battery charger only when
the surrounding temper
ature is
between 5
°C and 40 °C.
Error LED is lit.
Contact your service agent.