Replacing a broken or worn starter cord
Loosen the bolts that hold
the starter against the
crankcase and lift off the
starter unit.
Pull out the cord approx. 30
cm and lift it out of the cut-
out in the starter-pulley’s
periphery. Reset the recoil
spring by allowing the pulley
to slowly rotate backwards.
Loosen the screw in the
centre of the starter-pulley
and lift off the pulley. Insert
and secure the starter cord
in the starter pulley. Wind
on approx. 3 turns of the
cord on the pulley. Fit the
pulley on the recoil spring
so that the end of the recoil
spring hooks on the pulley.
Fit the screw in the centre of
the pulley. Thread the
starter cord through the hole
in the starter housing and
the starter handle. Tie a
good knot on the end of the
cord.
!
Tensioning the recoil spring
Lift up the starter cord from
the cut out on the pulley and
turn the pulley approx. 2
turns clockwise.
NOTE! Ensure the starter
pulley can be turned at least
a further 1/2 turn when the
starter cord is fully
extended.
Replacing a broken recoil spring
Lift up the starter pulley
(see section ”
Replacing a
broken or worn starter
cord”).
Bear in mind the
recoil spring is under
tension in the starter
housing.
Dismantle the recoil spring
by, with the inside of the
starter facing downwards,
gently knocking it against
the bench. If the spring flies
out when fitting, it is wound
from the outside towards
the centre.
Lubricate the recoil spring
with a thin layer of oil. Fit
the starter pulley and
tension the recoil spring.
Fitting the starter
Fit the starter by first pulling
out the starter cord and then
placing the starter in
position on the crankcase.
No slowly release the
starter cord so that the
pawls grip in the pulley.
Fit and tighten the screws
that hold the starter.
Starter
WARNING!
• The recoil spring sits in its tensioned posi-
tion in the starter housing and can with
careless handling fly out and cause personal
injury.
• When replacing the recoil spring or the
starter cord great care should be exercised.
Always wear protective glasses.
MAINTENANCE