Honeywell TC150 Weather Radio User Manual


 
23 24
2221
SETTING THE WEEKDAY AND SINGLE DAY
ALARMS
• Press ALARM button once to enter into the alarms
setting mode. The default alarm is a Weekday alarm.
The abbreviation “OFF” with a letter “ ” next to it
will be displayed, if the alarm has not been set previously.
• Press and hold the ALARM button for two seconds. The
hour digit will flash.
• Enter the hour using back panel UP ( ) or DOWN ( ).
• Press the ALARM again. The minute digits will flash.
• Enter the minutes using UP ( ) or DOWN ( ).
• Press the ALARM button again to confirm and the
weekday alarm time will be set.
• Set Single day alarm if desired in the same manner.
SETTING THE ICE WARNING ALARM
If Weekday or Single day alarm is set, the Ice Warning
Alarm can be programmed.
• Press the back panel ALARM button once to enter into
the Ice Warning Alarm setting mode. The abbreviation
OFF” with a “PRE-AL” next to it will be displayed.
• Press and hold the back panel ALARM button for two
seconds. The “30” number will flash, meaning that if
selected, the alarm will sound 30 minutes earlier than the
Weekday or Single alarm.
• Enter the desired minutes from 15 to 90 minutes in
15 minutes intervals, using UP ( ) or DOWN ( ).
• Press back panel ALARM button again to confirm and
exit from the alarm setting mode.
ACTIVATING THE ALARM
• Press ALARM ON/OFF button to enter into the alarms
mode.
• Press DOWN ( ) to activate or UP ( ) to deactivate
desired alarm. When alarms are activated, the
corresponding icons will be displayed.
SNOOZE
When any alarm sounds, press the SNOOZE/LIGHT button
to temporarily stop the alarm. After the SNOOZE/LIGHT is
depressed, the alarm sound will resume in eight minutes.
If the alarm is not disabled after that, it will sound for four
more minutes and then will stop by itself.
PRECAUTIONS
This product is engineered to give you years of satisfactory
service if handled carefully. Here are a few precautions:
• Do not immerse the units in water.
• Do not clean the units with abrasive or corrosive
materials. They may scratch the plastic parts and corrode
the electronic circuits.
• Do not subject the product to excessive force, shock,
dust, temperature, or humidity, which may result in
malfunctions, shorter lifespan, damaged batteries, and
damaged parts.
• Do not tamper with the units internal components. Doing
so will invalidate the warranty and may cause damage.
These units contain no user-serviceable parts.
• Use only fresh batteries. Do not mix new and old
batteries.
• Read the user's manual thoroughly before operating the
units.
SPECIFICATIONS
Main Unit
TIME
12/24 hour display in hh: mm format
Date format: month-day or day-month format
Day of the week is selectable in five languages (English, Spanish,
French, German, Italian)
Time zone manual adjustment
Dual two-minute crescendo alarms with 8 minutes snooze
Programmable ice warning alarm (Channel 1)
WEATHER
Rainfall
Proposed operating range: 0 to 1999.9mm/0 to 78.74 inch
Rainfall resolution: 0.04 inch (1mm)
Indoor Temperature
Proposed operating range: -5.0°C to +50.0°C/23.0°F to 122.0°F
Temperature resolution: 0.1°C/0.2°F
User-selectable (°F or °C) temperature display
LED backlight
Low battery indicator
Wall Mount or Desktop option
Remote Rain Gauge
Remote Rainfall Data
Proposed operating range: -5.0°C to +50.0°C/23.0°F to 122.0°F
RF transmission frequency: 433 MHz
RF transmission range: maximum 100 feet (30 meters)
Rainfall transmission cycle: approximately 183 seconds
Remote Temperature Sensor
Remote Temperature
Proposed operating range with alkaline batteries:
-20.0°C to + 70.0°C/-4.0°F to + 158°F
Proposed operating range with lithium batteries:
-38.8°C to + 70.0°C/-38.0°F to +158°F
Temperature resolution: 0.1°C/0.2°F
Low battery indicator
RF transmission frequency: 433 MHz
Maximum number of remote sensors: 3 (1 included)
RF transmission range: maximum 100 feet (30 meters)
Temperature transmission cycle: approximately 45 seconds
Power
Main unit: 2 AA size (UM-3) 1.5V batteries (not included)
Remote sensor: 2 AA size (UM-3) 1.5V batteries (not included)
Remote rain gauge: 2 AA size (UM-3) 1.5V batteries (not included)
Dimensions
Main unit: 2.75(L) x 5.43(H) x 1.02(D) inches
Remote sensor: 2.37(L) x 4(H) x 1(D) inch
Remote rain gauge: 6.49(L) x 6.89(H) x 4.72(D) inches