Hayter Mowers 41 Electric Lawn Mower User Manual


 
1.23
TROUBLE SHOOTING
PROBLEM POSSIBLE FAULT REMEDY
Motor fails to start. Mains supply socket dead. Test socket by plugging in
another appliance.
RCCB tripped. Remove mower plug and check
RCCB action. Check the supply
cable for any obvious signs of
damage and replace immediately
if defective. If no obvious faults
are found a serious fault is
indicated. Contact your Hayter
Dealer.
Plug pulled out of mains Re-engage plug.
socket.
Fuse failure. Fit a new 13 amp fuse.
Supply cable damaged. Disconnect from the mains and
check the supply cable for any
obvious signs of damage. Replace
immediately if defective.
Cutterblade obstructed. Disconnect from the mains and
remove any obstructions.
Cable socket pulled out of Re-engage cable socket.
switch control unit.
Motor will not stop. Faulty switch control unit. Ensure switch lever has returned
to the 'OFF' position. Disconnect
from the mains and contact your
Hayter Dealer.
Cutterblade runs on Faulty brake unit. Contact your Hayter Dealer.
excessively after switching
'OFF'.