4
1. Generator Air Intake
2. Engine Start/Stop Switch
3. Fuse
4. Optional Remote Panel Receptacle (Side View)
5. Generator AC Output Leads (Side View)
6. Fuel Primer Switch
7. Circuit Breaker
8. Starter Contactor
9. Fuel Inlet
10. Fuel Pump (Behind Access Panel)
11. Fuel Filter (Side View)
12. Oil Filter
13. Oil Drain Cap
14. Oil Dipstick
15. Air Filter (Behind Access Panel)
16. Oil Fill
17. Spark Plug
18 External Vacuum Port (model 004708-0 only)
Sectio n 1 – General Information
Recreational Vehicle Generator
Please record the following information from the generator DATA DECAL or information decal.
1. Model Number _____________________ 2. Serial Number __________________
3. kW Rating _________________________ 4. Rated Voltage __________________
I
t
r
e
,
e
w
a
D
W
AC
*
SERVICEACCESSPANEL
OIL LEVEL: CHECK DAILY
AIR FILTER: CLEAN PREFILTER
EVERY 100 HOURS.
REPLACE ELEMENT
EVERY 250 HOURS.
OIL & OIL FILTER:
CHANGE EVERY 100
(IF NECESSARY)
EVERY 500 HOURS.
HOURS. REPLACE PLUGS
PLUGS EVERY 100
INSPECT & CLEANSPARK PLUGS:
REPLACEMENT INFORMATION
*
PERFORM MORE OFTEN IN DUSTY CONDITIONS
AIR FILTER LOCATED BEHIND PANEL.
MAINTENANCE SCHEDULE
AIR FILTER P/N: 0D3262
070185OIL FILTER P/N:
SPARK PLUG P/N: 072347
OIL CAPACITY WITH FILTER:
0.8L/0.84QT
TEMPERATURE SAE VISCOSITY
32°F AND HIGHER
10°F TO 100°F
0°F TO 80°F
-20°F TO 50°F 5W-30
10W-30
15W-40
30
WHEN SERVICE OR PARTS ARE NEEDED IN
THE USA OR CANADA, CONTACT THE GENERAC
SERVICE LOCATOR AT 1-800-333-1322.
HOURS. (OR ANNUALLY)
PREFILTER P/N: 0D4511
FUEL FILTER P/N: 0D7515
FUEL FILTER: CHANGE EVERY 400
HOURS. (OR ANNUALLY)
*
*
PRIME
FUEL
STOP
START
30A
C.B.
15 A
FUSE
CONTROL CENTER
1
2
3
7
6
10/15
17
8
14,16
13
12
4
18
5
9/11
1.1 GENERATOR IDENTIFICATION