ELECTRICAL
**Ampere rating (on product data plate)
0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0
Cord Length Wire Size (A.W.G.)
25' 16 16 16 16 14 14
50'1616 16141412
100' 16 16 14 12 10 ---
WARNING
Keep the extension cord clear of the working area. Position the cord so that it will not get caught
on lumber, tools, or other obstructions while you are working with a power tool. Failure to do so
can result in serious personal injury.
WARNING
Check extension cords before each use. If damaged replace immediately. Never use the product
with a damaged cord since touching the damaged area could cause electrical shock resulting in
serious injury.
GROUND FAULT CIRCUIT INTERRUPTER
This unit is equipped with a Ground Fault Circuit Interrupter (GFCI), which guards against the
hazards of ground fault currents. An example of ground fault current is the current that would
, or earth.
GFCI plugs do not protect against short circuits, overloads, or shocks.
**Used on 12 gauge - 20 amp circuit.