Genie Z-45, Z-25 Utility Vehicle User Manual


 
Part No. 82595 Genie Z-45/25 DC & Genie Z-45/25J DC 17
Operator's ManualSecond Edition · First Printing
FUNCTION TESTS
At the Platform Controls
Test Emergency Stop
14 Push in the platform red Emergency Stop button
to the off position.
15 Activate each machine function control handle
or toggle switch.
Result: No functions should operate.
16 Pull out the red Emergency Stop button to the
on position.
Test the Horn
17 Push the horn button.
Result: The horn should sound.
Test the Foot Switch
18 Do not press down the foot switch and test each
machine function.
Result: The machine functions should not
operate.
Test Machine Functions
19 Press down the foot switch.
20 Activate each machine function control handle
or toggle switch.
Result: All boom/platform functions should
operate through a full cycle.
Note: Control the speed of boom functions by
adjusting the boom function speed controller. Drive
and steer functions are not affected by the boom
function speed controller.
Machines equipped with Platform Level Control
Disable Function: The platform level toggle switch
will not operate when the primary boom is raised
past the drive speed limit switch.
Test the Steering
21 Press down the foot switch.
22 Depress the thumb rocker switch on top of the
drive control handle in the direction identified by
the blue triangle on the control panel.
Result: The steer wheels should turn in the
direction that the blue triangles point on the
drive chassis.
23 Depress the thumb rocker switch in the
direction identified by the yellow triangle on the
control panel.
Result: The steer wheels should turn in the
direction that the yellow triangles point on the
drive chassis.