Genie Z-45, Z-25 Utility Vehicle User Manual


 
14 Genie Z-45/25 DC & Genie Z-45/25J DC Part No. 82595
Operator's Manual Second Edition · First Printing
Check the Batteries
Proper battery condition is essential to good
machine performance and operational safety.
Improper fluid levels or damaged cables and
connections can result in component damage and
hazardous conditions.
Electrocution hazard. Contact with
hot or live circuits could result in
death or serious injury. Remove all
rings, watches and other jewelry.
Bodily injury hazard. Batteries
contain acid. Avoid spilling or
contacting battery acid. Neutralize
battery acid spills with baking soda
and water.
Perform this test after fully
charging the batteries.
1 Put on protective clothing and eye wear.
2 Be sure that the battery cable connections are
tight and free of corrosion.
3 Remove the battery vent caps.
4 Check the battery acid level. If needed,
replenish with distilled water to the bottom of
the battery fill tube. Do not overfill.
5 Install the vent caps.
MAINTENANCE
Check the Tire Pressure
Tip-over hazard. An over-inflated
tire can explode which may
compromise machine stability and
cause the machine to tip over.
Tip-over hazard. The use of
temporary flat tire repair products
may lead to tire failure which could
compromise machine stability and
cause the machine to tip over.
Bodily injury hazard. An over-
inflated tire can explode and may
cause death or serious injury.
This procedure does not need to
be performed on machines
equipped with foam-filled tires.
1 Check each tire with an air pressure gauge and
add air as needed.
Tire pressure 100 psi 6.9 bar
Scheduled Maintenance
Maintenance performed quarterly, annually and
every two years must be completed by a person
trained and qualified to perform maintenance on this
machine according to the procedures found in the
service manual for this machine.
Machines that have been out of service for more
than three months must receive the quarterly
inspection before they are put back into service.