Genie Z-45, Z-25 Utility Vehicle User Manual


 
16 Genie Z-45/25 DC & Genie Z-45/25J DC Part No. 82595
Operator's Manual Second Edition · First Printing
FUNCTION TESTS
Test the Tilt Sensor
8 Turn the key switch to
platform control. Pull out
the platform red Emergency
Stop button to the on
position.
9 Open the turntable cover on
the side opposite the
ground controls and locate
the tilt sensor to the right of
the hydraulic pump.
10 Press down one side of the tilt sensor and hold
for 5 seconds.
Result: The alarm, located in the platform,
should sound.
Test Auxiliary Controls
11 Turn the key switch to ground control.
12 Pull out the red Emergency Stop button to the
on position.
13 Simultaneously hold the auxiliary
power switch on and activate each
boom function toggle switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.
1 Select a test area that is firm, level and free of
obstruction.
At the Ground Controls
2 Turn the key switch to ground control.
3 Pull out the red Emergency Stop button to
the on position.
Result: The beacon (if equipped) should flash.
Test Emergency Stop
4 Push in the red Emergency Stop button to the
off position.
Result: All functions should not operate.
5 Pull out the red Emergency Stop button to
the on position.
Test the Machine Functions
6 Do not hold the function enable
switch to either side. Attempt to
activate each boom and platform
function toggle switch.
Result: All boom and platform functions should
not operate.
7 Hold the function enable switch to either side
and activate each boom and platform function
toggle switch.
Result: All boom and platform functions should
operate through a full cycle. The descent alarm
(if equipped) should sound while the boom is
lowering.
Machines equipped with Platform Level Control
Disable Function: The platform level toggle switch
will not operate when the primary boom is raised
past the drive speed limit switch.