Generac RG03624ANSX Portable Generator User Manual


 
Maintenance
28 Owner’s Manual for Stationary Emergency Generators
Figure 5-3. Left Side View
NOTE: All normal maintenance and service items are easily accessible for consumer convenience. Wherever
possible, touch points are colored orange to provide for quick and easy recognition.
5.2 — Access Panels
Access panels are located at both the left and right sides of the enclosure.
5.2.1— Removal
1. Insert key into latch and rotate counterclockwise 1/2 turn. See Figure 5-4.
2. Raise panel using thumb latch.
Figure 5-4. Access Panel Key
5.2.2— Installation
1. Lower panel into position using thumb latch.
2. Insert key into latch and rotate clockwise 1/2 turn.
Battery
Coolant Drain
Oil
Drain Hose
Spark Plugs
Coolant Overflow
Reservoir
Key
Thumb Latch