Generac 9801-7 Portable Generator User Manual


 
11
10000EXL Extended Life Generator
120 Volt, 20 Amp Locking Type
Receptacle
Use a NEMA L5–20 plug with this receptacle. Connect a
3–wire cord set rated for 125 Volt AC loads at 20 Amps to
the plug (Figure 14).
Use this receptacle to operate 120 Volt AC, 60 Hz, single
phase loads requiring up to 2,400 watts (2.4 kW) of power
at 20 Amps.The outlet is protected by a 20 Amp
push–to–reset circuit breaker.
120 Volt AC, 20 Amp, Duplex
Receptacle
Each receptacle (Figure 15) is protected against overload by
a 20 Amp push–to–reset circuit breaker.
Use each receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125Volt AC loads at 20 Amps (or greater).
12 Volt DC, 10 Amp Receptacle
This receptacle allows you to recharge a 12 Volt
automotive or utility style storage battery with the battery
charge cables provided (Figure 16).
This receptacle can not recharge 6 Volt batteries and can
not be used to crank an engine having a discharged battery.
See the section “Charging a Battery” (page 8) before
attempting to recharge a battery.
Figure 15 — 120 Volt AC, 20 Amp,Duplex Receptacle
Figure 16 — 12 Volt DC, 10 Amp Receptacle
Figure 14 — 120 Volt AC, 20 Amp, Locking Receptacle
3-Wire Cord Set
Neutral
120V
Hot
Ground (Green)
NEMA L5-20